The probe isn’t the problem.The architecture is.

Reporter, quencher, sequence context and purification behave as one system. We design them that way.

TARGET TEMPLATERREPORTERgenerates signalREPORTERINTERNAL QUENCHERcloser to the reporter, lower backgroundINTERNALQUENCHERSEQUENCE CONTEXTneighboring bases can dim the dyeSEQUENCECONTEXT3′ QUENCHERblocks extension, adds quenching3′ QUENCHER
TARGET TEMPLATERREPORTERgenerates signalREPORTERINTERNAL QUENCHERcloser to the reporter, lower backgroundINTERNALQUENCHERSEQUENCE CONTEXTneighboring bases can dim the dyeSEQUENCECONTEXT3′ QUENCHERblocks extension, adds quenching3′ QUENCHER

Hydrolysis probe on its template with reporter, internal quencher, sequence context and 3′ quencher labeled

The dashed arc is the energy path from reporter to quencher. Moving the quencher inside the probe shortens it, which is why internal quenchers lower background.

Our assay oligos let you:

  1. Lower background with internal and terminal quencher architectures
  2. Add a channel without breaking the other four
  3. Know your cost per reaction before you order
  4. Confirm identity by mass spec, not by assumption
  5. Keep the same lot behavior run after run, with documented change control

Primers, probes and the problems around them.

Primers and hydrolysis probes

Assay-ready primers and probes across standard and far-red channels, with HPLC purification where the architecture calls for it and delivered volume guaranteed at 100 µM.

Far-red architectures are internally validated; performance is confirmed per assay.

FormatLab-ready, 100 µM
Delivered volume[X] µL, guaranteed
IdentityESI-MS
PurityHPLC
Illustrative quote layout. Values set per order.

Designed as a system

Architecture first

Reporter, quencher and sequence context are chosen together, not picked from separate menus.

Verified, not assumed

HPLC + mass spec

A clean trace can hide a missing dye, so both go on the certificate.

Adding a channel

Adding a fourth or fifth target is where panels break: crosstalk, far-red dropout and background creep. We build the new channel against your existing chemistry and hand back the data showing the other channels still behave.

Rescue: channels that won’t behave

Send the construct, the certificate and the curves. We diagnose the root cause before we quote a rebuild. You get the diagnosis; the fix stays proprietary.

  1. Intake: construct, certificate, curves
  2. Diagnose: root cause, with evidence
  3. Rebuild: redesigned architecture where needed
  4. Verify: analytical package and your data side by side

Second source and continuity

We build to your reference spec, hold dedicated lots, pre-stage materials and document every change, so a second source protects the assay you’ve already validated.

Lot[ID] reserved for continuity
Change controlDocumented and notified
MaterialsPre-staged for reorder
Continuity terms set per agreement.

Cost per usable microliter

Vendors quote synthesis scale. Labs use microliters at 100 µM. We put guaranteed delivered volume and cost per microliter on the quote.

Quoted price$[A]
Delivered volume at 100 µM[B] µL
Cost per usable µL$[A ÷ B]
Worked format only. No prices shown.

Priced on what you use

Usable microliters

Delivered volume at 100 µM, guaranteed on the quote.

Watch the architecture work.Then change it.

Watch a hydrolysis probe anneal, get cleaved and light up, then see what an internal quencher and a neighboring guanine change.

Terminal quencher

TEMPLATERpolymerasecycleSIGNALBACKGROUND
TEMPLATERpolymerasecycleSIGNAL

BACKGROUND

A terminal quencher sits at the far end of the probe. The distance to the reporter leaves some background signal.

Internal quencher

TEMPLATERpolymerasecycleSIGNALBACKGROUND
TEMPLATERpolymerasecycleSIGNAL

BACKGROUND

An internal quencher sits close to the reporter, designed to lower background before cleavage.

Compare

TEMPLATERpolymerasecycleSIGNALBACKGROUND
TEMPLATERpolymerasecycleSIGNAL

BACKGROUND

Same reaction, two architectures. The internal quencher is designed to give a cleaner baseline.

Sequence context

RACTCCATGAGSIGNAL DIMSDYE · NEIGHBORING NUCLEOBASES
RACTCCATGAGSIGNAL DIMSDYE · NEIGHBORING NUCLEOBASES

DYE · NEIGHBORING NUCLEOBASES

A guanine next to the dye can dim it. Placement of nucleobases is part of the design.

ⓘ Illustrative curves. Example of the evidence delivered with your order.

Every dye has a color.Every color has a job.

A reporter absorbs one color of light and gives back another. Where those colors sit decides which channel it reads in, and how cleanly it separates from its neighbors.

Spectra

Seven reporters laid across the visible spectrum. Each is drawn in its own emission color, with its excitation dashed behind it.

One dye, one color

FAM absorbs 495 nm light and gives back 520 nm, which reads as green. Free of its quencher, the signal appears.

Multiplex

Well separated

Four reporters spaced across the spectrum. Each channel mostly collects its own dye, so the panel stays clean.

Crowded

Four reporters packed into the yellow to orange. Neighboring emission leaks into each channel, which is where multiplex panels break.

Typical reporter wavelengths
DyeEx (nm)Em (nm)Stokes (nm)Emission color
FAM49552025Green
HEX53555621Yellow-green
Cy355057020Yellow
TAMRA55558025Yellow-orange
ROX57560227Orange
Texas Red59661519Orange-red
Cy564967021Deep red

ⓘ Illustrative curves drawn from typical absorbance and emission maxima. Filter windows and bleed-through are schematic. Confirm against your instrument’s filter set and your own spectra.

See the reporter building blocks

Four ways a probepasses or fails.

A probe has to work optically, thermally, enzymatically and in manufacturing, all at once. We evaluate every architecture against each before it ships.

Optical design

Reporter, quencher and channel, chosen together.

wavelength · nmNORMALIZED INTENSITYREPORTER EMISSIONquencher absorbanceoverlap
wavelength · nmNORMALIZED INTENSITYREPORTER EMISSIONquencher absorbanceoverlap

quencher absorbance

Thermodynamics

Binding strength and specificity under your conditions.

temperature · °C−dF/dTMATCHED TARGEThigher Tmmismatch
temperature · °C−dF/dThigher Tmmismatch

MATCHED TARGET

higher Tm

Enzymatic behavior

How the probe is processed during amplification.

DURING EXTENSIONpolymeraseCLEAVED REPORTERaccessible to the enzyme, released to signal
DURING EXTENSIONpolymeraseCLEAVED REPORTERaccessible to the enzyme, released to signal

accessible to the enzyme, released to signal

Manufacturability

Can it be made, purified and repeated lot to lot?

retention · minA260N-1 SHOULDERpurification burden is part of the design
retention · minA260N-1 SHOULDERpurification burden is part of the design

purification burden is part of the design

Common questions.

Can you match a probe I already use from another supplier?

Yes. Send the reference certificate and any performance benchmarks, and we build to a defined reference. If no reference data exists, we design the architecture ourselves, scoped separately.

Why do you report mass spec as well as HPLC?

HPLC shows what eluted together. Mass spec confirms what is actually in the tube. For labeled probes, especially far-red dyes, the two can disagree, and you should know when they do.

What does “usable microliters” mean on a quote?

The volume you receive at 100 µM, ready to use, so you can compare cost per reaction directly.

What should I send to get started?

Your sequence, what the assay has to do (targets, channels and instrument), and a reference certificate or curves if you have them. A chemist reviews it and sends back a plan before synthesis starts, so you know the architecture, the purification route and the evidence you’ll receive up front.

Bring us your worst channel.We’ll tell you what the molecule is doing.

  1. Send the construct, certificate and curves
  2. Get a root-cause diagnosis before a quote
  3. Decide on a rebuild with the evidence in hand