CD68
Recombinant ID:
3261
Gene of Interest
Gene Synonyms:
CD68
Protein Names:
Macrosialin (Gp110) (CD antigen CD68)
Accession Data
Organism:
Homo sapiens (Human)
Mass (kDa):
37408
Length (aa):
354
Metal Binding:
Pending Verification
Proteomics (Proteome ID):
Macrosialin (Gp110) (CD antigen CD68)
Proteomics (Chromosome):
UP000005640
Disease:
N/A
Mutagenesis:
N/A
Sequence:
MRLAVLFSGALLGLLAAQGTGNDCPHKKSATLLPSFTVTPTVTESTGTTSHRTTKSHKTTTHRTTTTGTTSHGPTTATHNPTTTSHGNVTVHPTSNSTATSQGPSTATHSPATTSHGNATVHPTSNSTATSPGFTSSAHPEPPPPSPSPSPTSKETIGDYTWTNGSQPCVHLQAQIQIRVMYTTQGGGEAWGISVLNPNKTKVQGSCEGAHPHLLLSFPYGHLSFGFMQDLQQKVVYLSYMAVEYNVSFPHAAQWTFSAQNASLRDLQAPLGQSFSCSNSSIILSPAVHLDLLSLRLQAAQLPHTGVFGQSFSCPSDRSILLPLIIGLILLGLLALVLIAFCIIRRRPSAYQAL
Function [CC]:
Could play a role in phagocytic activities of tissue macrophages, both in intracellular lysosomal metabolism and extracellular cell-cell and cell-pathogen interactions. Binds to tissue- and organ-specific lectins or selectins, allowing homing of macrophage subsets to particular sites. Rapid recirculation of CD68 from endosomes and lysosomes to the plasma membrane may allow macrophages to crawl over selectin-bearing substrates or other cells.
Analysis Summary:
Alternative sequence (2); Chain (1); Compositional bias (1); Disulfide bond (2); Glycosylation (9); Natural variant (4); Region (2); Repeat (2); Sequence conflict (1); Signal peptide (1); Topological domain (2); Transmembrane (1); Highly expressed by blood monocytes and tissue macrophages. Also expressed in lymphocytes, fibroblasts and endothelial cells. Expressed in many tumor cell lines which could allow them to attach to selectins on vascular endothelium, facilitating their dissemination to secondary sites. {ECO:0000269|PubMed:18405323}.
Reagent Data
Name:
Macrosialin (Gp110) (CD antigen CD68)
Subcategory:
Recombinant
Source:
HEK293
Species:
Format:
Lyophilized
pH:
7.4-7.5
Formulation:
Sterile-filtered colorless solution
Formulation Concentration:
1mg/ml
Buffer Volume:
Standard
Buffer Solution:
PBS
Metal Chelating Agents
Determined:
SDS-PAGE
Purity:
> 98%
Validated:
RP-HPLC
Sample Handling
Storage:
-20°C
Stability:
This bioreagent is stable at 4°C (short-term) and -70°C(long-term). After reconstitution, sample may be stored at 4°C for 2-7 days and below -18°C for future use.
Preparation:
Reconstitute in sterile distilled H2O to no less than 100ug/ml; dilute reconstituted stock further in other aqueous solutions if needed. Please review COA for lot-specific instructions. Final measurements should be determined by the end-user for optimal performance.
Request a Datasheet
We'll respond with your requested information within a day!